  The use of heat pumps has been held back largely by skepticism about advertisers’ claims that heat pumps can provide as many as two units of thermal energy for each unit of electrical energy used, thus apparently contradicting the principle of energy conservation.

  Heat pumps circulate a fluid refrigerant that cycles alternatively from its liquid phase to its vapor phase in a closed loop. The refrigerant, starting as a low-temperature, low-pressure vapor, enters a compressor driven by an electric motor. The refrigerant leaves the compressor as a hot, dense vapor and flows through a heat exchanger called the condenser, which transfers heat from the refrigerant to a body of air. Now the refrigerant, as a high-pressure, cooled liquid, confronts a flow restriction which causes the pressure to drop. As the pressure falls, the refrigerant expands and partially vaporizes, becoming chilled. It then passes through a second heat exchanger, the evaporator, which transfers heat from the air to the refrigerant, reducing the temperature of this second body of air. Of the two heat exchangers, one is located inside, and the other one outside the house, so each is in contact with a different body of air: room air and outside air, respectively.

  The flow direction of refrigerant through a heat pump is controlled by valves. When the refrigerant flow is reversed, the heat exchangers switch function. This flow-reversal capability allows heat pumps either to heat or cool room air.

  Now, if under certain conditions a heat pump puts out more thermal energy than it consumes in electrical energy, has the law of energy conservation been challenged? No, not even remotely: the additional input of thermal energy into the circulating refrigerant via the evaporator accounts for the difference in the energy equation.

  Unfortunately there is one real problem. The heating capacity of a heat pump decreases as the outdoor temperature falls. The drop in capacity is caused by the lessening amount of refrigerant mass moved through the compressor at one time. The heating capacity is proportional to this mass flow rate: the less the mass of refrigerant being compressed, the less the thermal load it can transfer through the heat-pump cycle. The volume flow rate of refrigerant vapor through the single-speed rotary compressor used in heat pumps is approximately constant. But cold refrigerant vapor entering a compressor is at lower pressure than warmer vapor. Therefore, the mass of cold refrigerant - and thus the thermal energy it carries - is less than if the refrigerant vapor were warmer before compression.

  Here, then, lies a genuine drawback of heat pumps: in extremely cold climates - where the most heat is needed - heat pumps are least able to supply enough heat.

  1. The primary purpose of the text is to

  [A] explain the differences in the working of a heat pump when the outdoor temperature changes.

  [B] contrast the heating and the cooling modes of heat pumps.

  [C] describe heat pumps, their use, and factors affecting their use.

  [D] advocate the more widespread use of heat pumps.

  2. The author resolves the question of whether heat pumps run counter to the principle of energy conservation by

  [A] carefully qualifying the meaning of that principle.

  [B] pointing out a factual effort in the statement that gives rise to this question.

  [C] supplying additional relevant facts.

  [D] denying the relevance of that principle to heat pumps.

  3. It can be inferred from the text that, in the course of a heating season, the heating capacity of a heat pump is greatest when

  [A] heating is least essential.

  [B] electricity rates are lowest.

  [C] its compressor runs the fastest.

  [D] outdoor temperatures hold steady.

  4. If the author’s assessment of the use of heat pumps (lines 1-4) is correct, which of the following best expresses the lesson that advertisers should learn from this case?

  [A] Do not make exaggerated claims about the products you are trying to promote.

  [B] Focus your advertising campaign on vague analogies and veiled implications instead of on facts.

  [C] Do not use facts in your advertising that will strain the prospective client’s ability to believe.

  [D] Do not assume in your advertising that the prospective clients know even the most elementary scientific principles.

  5. The text suggests that heat pumps would be used more widely if

  [A] they could also be used as air conditioners.

  [B] they could be moved around to supply heat where it is most needed.

  [C] their heat output could be thermostatically controlled.

  [D] people appreciated the role of the evaporator in the energy equation.


  考研英语考察的知识点和考察方式都是“精确”的,特别是在的分大头的阅读理解上面。所以大家要勤刷题哦。


相关推荐:

2018考研英语阅读真题(10)

2018考研英语阅读真题(11)

2018考研英语阅读真题(12)

2018考研英语阅读真题(13)

免费领取资料

独家考研团队题型预测,考研英语近20年真题解析+高分范文,政治复习资料全集、最新政治热点,数学常考公式以及专业课等资料

方法1:扫码添辅导老师微信

微信号:xhdkaoyan

方法2:填写个人信息老师亲自联系您

特色课程
相关文章推荐 更多>
    考研群 扫码领资料
    • 考研英语历年真题

      获取

      扫码添加老师微信

      请注明:姓名-公司-职位
      以便审核进群资格,未注明
      则拒绝

    • 考研数学历年真题

      获取

      扫码添加老师微信

      请注明:姓名-公司-职位
      以便审核进群资格,未注明
      则拒绝

    • 考研政治各科历年真题

      获取

      扫码添加老师微信

      请注明:姓名-公司-职位
      以便审核进群资格,未注明
      则拒绝

    • 专业课历年真题

      获取

      扫码添加老师微信

      请注明:姓名-公司-职位
      以便审核进群资格,未注明
      则拒绝

    • 课程录播(视频)

      获取

      扫码添加老师微信

      请注明:姓名-公司-职位
      以便审核进群资格,未注明
      则拒绝

    在线课堂

    排行榜 更多 >